Technical features, Salidas / outputs, Configura tion – CIRCUTOR CVMk2 Series User Manual

Page 72: Features value unit analogical outputs, Static outputs, Maximum r, 25 ω connections, Mechanical, An example of the wiring of the expansion cards is

Advertising
background image

72

CVM

k2

CONFIGURA

TION

4.7.6.6. Technical Features

FEATURES

VALUE

UNIT

ANALOGICAL OUTPUTS

Output range

± 5

mA c.c

Lineality

1

%

Load resistance

1.500

Ω

Output range

4.000

points

STATIC OUTPUTS

Nominal voltage

150 / 250

VDC/VAC

Nominal current

100

mA

Maximum current t=10ms

< 150

mA

Maximum power of dissipation

0,8

W

Maximum R

on

25

Ω

CONNECTIONS

Wire section (Cu)

0,05..1 (AWG 30...18)

mm

2

Maximum torque

0,3

Nm

MECHANICAL

Protecction

IP 20

An example of the wiring of the expansion cards is:

1

2

3

4

5

6

7

8

9

Carga externa
External load

D

A

D

A

SALIDAS / OUTPUTS

1

2

3

4

5

6

7

8

9

24 Vdc

Bobina auxiliar
Auxiliary relay

SALIDAS / OUTPUTS

COMM