Decrement – Zilog Z86193 User Manual

Page 182

Advertising
background image

Z8

®

CPU

User Manual

UM001604-0108

Instruction Description

175

Decrement

Syntax

DEC dst

Instruction Format

Operation

dst

dst–1

The contents of the destination operand are decremented by one.

Address modes R or IR can be used to specify a 4-bit Working Register. In this format, the
destination Working Register operand is specified by adding

1110b

(

Eh

) to the high nibble

of the operand. For example, if Working Register R12 (CH) is the destination operand, then

ECh

is used as the destination operand in the Op Code.

Example 1

If Working Register R10 contains 2A%, the statement:

DEC R10

Op Code: 00 EA

leaves the value

29h

in Working Register R10. The Z, V, and S Flags are cleared.

Example 2

If Register

B3h

contains

CBh

, and Register

CBh

contains

01h

, the statement:

DEC @B3h

Op Code: 01 B3

leaves the value

00h

in Register

CBh

. The Z Flag is set, and the V and S Flags are cleared.

Cycles

OPC

(Hex)

Address

Mode dst

OPC

dst

6

00

R

6

01

IR

Flag

Description

C

Unaffected

Z

Set if the result is zero; cleared otherwise

S

Set if the result of bit 7 is set (negative); cleared otherwise

V

Set if arithmetic overflow occurs; cleared otherwise

D

Unaffected

H

Unaffected

E

dst

Note: