Instruction Description

185

Increment Word

Syntax

INCW dst

Instruction Format

Operation

dst

←

dst–1

The contents of the destination (which must be an even address) operand is decremented
by one. The destination operand can be a Register Pair or a Working Register Pair.

Address modes RR or IR can be used to specify a 4-bit Working Register Pair. In this for-
mat, the destination Working Register Pair operand is specified by adding

1110b

(

Eh

) to

the high nibble of the operand. For example, if Working Register Pair R12 (CH) is the des-
tination operand, then

ECh

is used as the destination operand in the Op Code.

Example 1

If Register Pairs

30h

and

31h

contain the value

0AF2h

, the statement:

INCW 30h

Op Code: A0 30

leaves the value

0AF3h

in Register Pair

30h

and

31h

. The Z, V, and S Flags are cleared.

Cycles

OPC

(Hex)

Address Mode

dst

OPC

dst

10

A0

RR

10

A1

IR

10

A0

R

Flag

Description

C

Unaffected

Z

Set if the result is zero; cleared otherwise.

S

Set if the result of bit 7 is set (negative); cleared otherwise.

V

Set if arithmetic overflow occurs; cleared otherwise.

D

Unaffected

H

Unaffected

E

dst

Note: