Page line audio detect output contact – GAI-Tronics LE300-IP Page/Party Line Extender User Manual

Page 11

Advertising
background image

Pub. 42004-488C

M

ODEL

LE300-IP

P

AGE

/P

ARTY

®

L

INE

E

XTENDER

P

AGE

8 of 68

e:\standard ioms - current release\42004 instr. manuals\42004-488c.doc
09/14

Page Line Audio Detect Output Contact

The Model LE300-IP Line Extender provides a contact closure output that activates whenever audio is
detected on the page line. The contact can be set to close when audio is detected at the local page line, the
remote page line, or both. Typically this contact is used in conjunction with the Page Line Audio
Monitoring Output to provide a control contact to external devices or systems when page line audio is
present. The contact remains active for 1 second after the audio is no longer detected. DIP switch SW5
positions 6 and 7 enables or disables the output contact. Refer to Figure 6 for the location of switch SW5
on the Main PCBA and the tables below for setting options.

Table 4. Page Line Audio Detect Contact Main PCBA

SW5-6

SW5-7

Audio Detect Contact Operation

Closed

Closed

Disabled

Open

Closed

Local page line audio activates the contact

Closed

Open

Remote page line audio activates the contact

Open*

Open*

Both Local and Remote page line audio activates the contact

N

OTES

: 1. Changes to this parameter take effect without cycling power.

2.

*Indicates

default

position.

Page Line FSK Data Transmission (SmartSeries Systems)

A pair of Model LE300-IP Line Extenders re-generates the FSK data transmission between two
SmartSeries Page/Party

®

system cables. FSK data transmission occurs on the page line allowing

SmartSeries Page/Party

®

stations to communicate with the ADVANCE system control cabinet. For proper

operation, both line extenders must have this feature enabled by setting DIP switch SW5 position 1. Refer
to Figure 6 for the location of switch SW5 on the Main PCBA and Table 5 below for setting options.

Table 5. Page Line FSK Transmission on Main PCBA

SW5-1

Page Line FSK Transmission

Open*

FSK data is disabled.

Closed

FSK data is enabled.

N

OTES

: 1. Changes to this parameter take effect without cycling power.

2.

*Indicates

default

position.

N

OTE

: FSK operation and VLC operation (described below) cannot be enabled at the same time.

FSK operation is only used with SmartSeries systems.

VLC operation is only used within NON-SmartSeries systems. If both 50 kHz VLC and FSK are
enabled at the same time, neither feature will function correctly.

Advertising