IP Bandwidth Requirements

Each pair of LE300-IP Line Extenders requires approximately 3 Mb of bandwidth on the network. Actual
bandwidth usage can be adjusted via settings on the IPmux-24. Refer to the IPmux-24 user manual for
details.

Rules for Interconnecting More than Two Model LE300-IPs

When connecting more than two Model LE300-IPs together, these rules must be followed.
 A maximum of two Model LE300-IP pairs can be connected in series when the series connections are

made using Page/Party

®

cable as shown below.

Figure 10. Maximum Series Connections

When Model LE300-IPs are connected in series, a problem can arise when training the echo
cancellation. If more than one Model LE300-IP is training echo cancellation on a signal line at the
same time, then none of them will train echo cancellation properly. To prevent this, power each line
extender one at a time. Wait for the echo cancellation to complete on the first line extender before
powering the second.

 A maximum of eight pairs of Model LE300-IPs can be connected in parallel. Parallel connections

must be made using the LVDS as shown below.

Figure 11. Maximum Parallel Connections