Contact Closure Input Connections
Contact inputs are typically connected to switches or mechanical relay contacts. Five inputs are available
with each input requiring two conductors. Connect the normally open contact across the top and bottom.
If using a solid state switch as the input device, observe polarity of the connection: (−) on bottom, and (+)
on top. Each input cable connection point is labeled next to the terminal block TB8 and TB9 as shown
below.
Figure 14. Input Contact Terminals
Table 28. TB8 and TB9
Terminal Designator Description
TB8
Input 1 (+)
Input contact 1
TB8
Input 1 (−)
TB8
Input 2 (+)
Input contact 2
TB8
Input 2 (−)
TB8
Input 3 (+)
Input contact 3
TB8
Input 3 (−)
TB9
Input 4 (+)
Input contact 4
TB9
Input 4 (−)
TB9
Input 5 (+)
Input contact 5
TB9
Input 5 (−)