Page Line Ground Fault Detection

DC resistance from either L1 or L2 to ground for fault ..................................................................

5,000 

DC resistance from either L1 or L2 to ground for no fault .............................................................

8,000 

Minimum ground fault duration for detection ............................................................. 10 seconds (nominal)
Minimum no ground fault duration for detection ........................................................ 10 seconds (nominal)
No ground fault to ground fault propagation delay ..............................

20 seconds includes detection time

Ground fault to no ground fault propagation delay ..............................

20 seconds includes detection time

N

OTE

: Rapidly changing ground fault conditions may or may not be detected.

Page Line Ground Fault Generation

Resistance when generating ground fault .......................................................................... 3.3 k

 (nominal)

Resistance when not generating ground fault ....................................................................................

1 M

N

OTE

: The resistance is from the center tap of the page line coupling transformer to ground.

Party Line Off-hook detection

DC resistance between L1 and L2 for off-hook .................................................................................

300 

DC resistance between L1 and L2 for on-hook ............................................................................

30,000 

Minimum off-hook duration for detection ........................................................... 50 milliseconds (nominal)
Minimum on-hook duration for detection ...................................................................... 5 seconds (nominal)
On-hook to off-hook propagation delay ................................................

0.5 second includes detection time

Off-hook to on-hook propagation delay ...............................................

10 seconds includes detection time

N

OTE

: Rapidly changing off-hook or on-hook conditions may or may not be detected.

Contact Outputs

Contact output type .......................................................................................... DPDT miniature signal relay
Switching power ....................................................................................................

30 W dc (resistive load)

62.5 VA ac (resistive load)

Switching voltage..........................................................................................................................

110 V dc

125 V ac

Switching current ................................................................................................................................

1.0 A

Minimum switching capacity ............................................................................. 10

A, 10 mV dc (nominal)

N

OTE

: When neither the T1/E1 Link nor the LVDS link is detected, the contact outputs are de-energized.