GAI-Tronics LE300-IP Page/Party Line Extender User Manual

Page 67

Advertising
background image

Pub. 42004-488C

M

ODEL

LE300-IP

P

AGE

/P

ARTY

®

L

INE

E

XTENDER

P

AGE

64 of 68

e:\standard ioms - current release\42004 instr. manuals\42004-488c.doc
09/14

Contact Inputs

Dry contact input open resistance .................................................................................................

20,000 

Dry contact input closed resistance ....................................................................................................

200 

Wet contact input open voltage ........................................................................ 2.6

 voltage  +3.6 volts dc

Wet contact input closed voltage ...................................................................... 0.0

 voltage  0.23 volts dc

Contact input allowed voltage ......................................................................... 0.0

 voltage  +3.6 volts dc

Contact input sink current ...........................................................................................................

1.0 mA dc

Contact input state duration ...............................................................................................................

50 ms

Contact input to contact output delay ................................................................................................

50 ms

Contact input to contact output jitter ..................................................................................................

10 ms

Contact input to contact output pulse width tolerance .......................................................................

10 ms

N

OTES

:

1. Rapidly changing contact inputs may or may not be detected.
2. Contact input to contact output specifications does not include the effects of relay bounce.
3. The contact input’s negative terminal is tied directly to the LE300-IP’s signal ground.
4. Wet contact input voltages are measured at the input terminals on the I/O Connection Module.
5. The “wet contact input closed voltage” may be difficult to achieve when connecting a bipolar open

collector output to a contact input.

6. A driving high wet contact input will source current to the LE300-IP when the LE300-IP is not

powered. This current may or may not prevent the LE300-IP from powering up properly.

7. Be aware of the ground loop(s) formed when using wet contact inputs.

Mechanical

Enclosure Material ................................................................................................................................. Steel
Unit dimensions ....................................... 20.0 H

 20.0 W  6.9 D inches (508  508  173 mm) nominal

Unit weight........................................................................................................................................... 40 lbs.
Enclosure Environmental Rating .................................................................................................... NEMA 4

Environmental

Temperature range ................................................................................. 0° C to +50° C (+32° F to +122° F)
Relative humidity ................................................................................................... 10–85% non-condensing