GAI-Tronics LE300-IP Page/Party Line Extender User Manual

Page 53

Advertising
background image

Pub. 42004-488C

M

ODEL

LE300-IP

P

AGE

/P

ARTY

®

L

INE

E

XTENDER

P

AGE

50 of 68

e:\standard ioms - current release\42004 instr. manuals\42004-488c.doc
09/14

Table 33. Main PCBA

Designator Type

Function

J1

RJ-45 receptacle LVDS data “out”

J2

RJ-45 receptacle LVDS data “in”

J3 DB-25

connector

Connects to J1 on Input/Output Termination Connection Module via
25-pin ribbon cable.

J4 DB-25

connector

Connects to J1 on Page/Party

®

Termination Connection Module via

25-pin ribbon cable.

P1 N/A

Not

installed

P2

Post header

No connection - used during production testing of PCBA

P3 N/A

Not

installed

P4

Post header

No connection - used during production testing of PCBA

P5

Jumper clip

Page line ground fault detector (enabled/disabled)

P6, P7

Jumper clip

Party line #5 off-hook detector (enabled/disabled)

P8, P9

Jumper clip

Party line #4 off-hook detector (enabled/disabled)

P10, P11

Jumper clip

Party line #3 off-hook detector (enabled/disabled)

P12, P13

Jumper clip

Party line #2 off-hook detector (enabled/disabled)

P14, P15

Jumper clip

Party line #1 off-hook detector (enabled/disabled)

P16

Terminal block Page line monitor output - Terminals 1 and 3

No connection - Terminal 2

P17, P18

Terminal block Power 48 V dc (+) - Terminal 1

Power 48 V dc (−) - Terminal 2

P19

Terminal block T1/E1 Data TX (ring) - Terminal 1

T1/E1 Data TX (tip) - Terminal 2
T1/E1 Data RX (ring) - Terminal 3
T1/E1 Data RX (tip) - Terminal 4

P20

Jumper clip

T1/E1 receive transformer center tap floating/grounded.

P21

Jumper clip

T1/E1 transmit transformer center tap floating/grounded.

PB1 Push-button

switch

Used to retrain the echo cancellation circuit.

SW1 Rotary

HEX

switch

Used for diagnostic purposes. Set to 0 during normal operation.