Supervisory Mounting
1. Disconnect the power from the ICP9000 Navigator MCU and remove all attached cables from the
rear cover. Remove the stand-offs.
2. Mount the Telco Interface (where applicable) to the Supervisory unit on the rear of the console.
Refer to Figure 31. Position the Telco Interface so that the three DB25 connector plugs line up with
the DB25 connector receptacles on the rear panel.
3. Secure the Telco Interface with the supplied #6-32 screws shown in Figure 31, tightening them until
the unit is snug against the rear panel.
4. Reattach all cables and reconnect the power.
N
OTE
: The Supervisory unit input connectors and output connectors can each have a separate Telco
Interface unit attached.