Gasboy TopKAT PLUS User Manual
Page 35

MDE-5013C TopKAT™ PLUS Installation Manual · February 2015
Page 3-9
Connections to TopKAT PLUS - Pedestal Mounted Units
TopKAT PLUS Installation Procedures
Connections to TopKAT PLUS - Pedestal Mounted Units
All connections to the post mounted TopKAT PLUS must be performed to the terminal block
located at the bottom of the TopKAT PLUS box (see
and
The required connections are:
• Dispenser wiring connections (mechanical dispensers):
- Pulser (low voltage)
- In use signal (high voltage)
- Solenoid valve (high voltage)
• Communications (Atlas 9800 electronic dispensers):
- Pump communication line (RS-485)
• Mains AC power and ground (electronic and mechanical dispensers)
• LAN connection. LAN cable is directly connected to LAN2 connection on the OrCU.
Figure 3-7: TopKAT PLUS Terminal Block - Mechanical Pump