Module wiring & connections, Vcm-x component & systems wiring 108, Hvac – Orion System VCM-X E-BUS Component User Manual

Page 108: Hssc cable, 24 vac, When used with orion vcm-x e-bus controller, Aaon wshp-x2 wiring - single circuit 1

Advertising
background image

Module Wiring & Connections

VCM-X Component & Systems Wiring

108

Figure 84: OE334-26-WSHP-X2 WSHP-X2 Controller Single Circuit Wiring to VCM-X E-BUS Controller

FILENAME

DATE:

S. Olson

DESCRIPTION:

PAGE

DRAWN BY:

When Used With Orion VCM-X E-BUS Controller

JOB NAME

06/05/15

WSHPX2-Wr1.CDR

AAON WSHP-X2 Wiring - Single Circuit

1

Wiring For WSHP-X2 When Used With Orion VCM-X E-BUS Controller

Connect To Other

WattMaster-Approved

E-BUS Expansion Module(s)

WARNING!! Observe
Polarity! All boards
must be wired with
GND-to-GND and 24
VAC-to-24 VAC.
Failure to observe
polarity could result in
damage to the boards.

HSSC Cable

WATTMASTER CONTROLS

Y 102374 REV 0

S

MADE IN USA

NOTE:

NORMALLY OPEN AND

RATED FOR 24 VAC POWER
ONLY

ALL RELAY OUTPUTS

ARE

COMP. A2 ENABLE

COMP. A1 ENABLE

R1

R4
R5

R3

R2

COMM

COMP. B1 ENABLE

COMP. B2 ENABLE

ALARM OUTPUT

HVAC

24 VAC

AOUT1
AOUT2

GND

T1

WATER POF

BIN6

COM

E

LEAVING WATER

TEMPERATURE

SENSOR

SIG 1

GND

+V

BK

RD
WH

CIRCUIT A
SUCTION PRESSURE
TRANSDUCER

SIG 1

GND

+V

BK

RD
WH

CIRCUIT B
SUCTION PRESSURE
TRANSDUCER

OE334-26-WSHP-X2

Water Source

Heat Pump X2 Module

AOUT3
AOUT4

COMP A1
COMP A2

COMP B1
COMP B2

SEE
NOTE
BELOW

NOTE:
DIGITAL COMPRESSORS = 1.5-5VDC

VFD COMPRESSORS = 0-10VDC

WattMaster Label

#S

000063

Rev.: 1B

W

E-BUS

HSSC

CONNECT

M

ENTER

UP

DOWN

ALARM

MENU

OE334-26-WSHP-X2 WSHP-X2 MODULE

AAON NO.: V48820

+24 V

A

C

GND

www.orioncontrols.com

www.aaon.com

- COMP A1 EN

- HEAT ENABLE

- COMP A2 EN

- H2O POF A

- COMP B1 EN

- H2O POF B

- COMP B2 EN

- COMMON

GND

- LEAVING WATER TEMP

- GROUND

- LEAVING WATER TEMP

AOUT1

- COMP A1

DIGITAL/VFD COMPRESSORS

A1, A2, B1, B2

RELAY CONTACT RATING

IS 1 AMP MAX @ 24 VAC

COMP. A2 ENABLE

COMP. A1 ENABLE

R1

R2

R3

R4

R5

RC

RELAY COMMON

COMP. B1 ENABLE

COMP. B2 ENABLE

ALARM OUTPUT

CONNECT TO
CNTLR C2
TERM.

+5V

PRES

GND

+5V

PRES

GND

SUCT. PR. SENSOR
PRES 1=A1, PRES 2=A2
PRES 3=B1, PRES 4=B2

NOT USED
PRES 1=A1, PRES 2=A2
PRES 3=B1, PRES 4=B2

+5 NOT USED, PRES TO P6 & GND TO P5

+5 TO RED, PRES TO WHT & GND TO BLK

DIGITAL COMRESSORS

NON-DIGITAL COMPRESSORS

AOUT2

- COMP A2

AOUT3

- COMP B1

AOUT4

- COMP B2

E-BUS

HSSC

CONNECT

BIN1

BIN2

BIN3

BIN4

BIN5

BIN6

BIN7

COM

T 1

T 2

Connect To VCM-X E-BUS

Controller

WSHP-X2 Controller Wiring When Used With The VCM-X E-BUS