VCM-X Component & Systems Wiring

29

Networked Multiple Loop System Connections & Wiring

EPROM

U3

U5

RAM

CX

2

1

U2

R1

C3

U4

CX3

CX4

YS101818P552

PROCESSORPBOARD

CX5

C1

U1

R2

CX1

CX6

WDOG

U6

PHILIPS

D1

P1

X1

C2

C4

0-10V

4-20mA

THERM

R27

R31

D4

GN

D

24VA

C

TB1

D5

C1

1

U12

LED 2

POWER

V1

R25

R26

C7

CX

15

CX

13

PROC.

DRIVER

LOOP

DRIVER

LOCAL

LOOP

GN

D

AIN 2

AIN

1

+5V

TB2

P4

OFF=0-5V

AIN2

AIN1

0-10V

4-20mA

THERM

TB3

U15

LD5

LD6

U13

C8

LED 1

RV

1

R4

VREF

CX

2

U1

1

YS101900PMINILINK

POLLING

DEVICE

REV

. 1

OFF

1

2

4

8

16

32

CX

14

NETWORK

DRIVER

RN3

SH

LD

SHLD

T

T

TB4

R

R

U14

NETWORK

LOOP

P5

ADD

P3

R24

LD4

C9

U10

RN2

SW1

R30

X2

R29

R28

C10

U6

CX

6

CX

1

U7

U1

X1

C3

C1

R3

CX7

EPROM

U3

U5

RAM

CX2

1

U2

R1

C3

U4

CX3

CX4

YS101818P552

PROCESSORPBOARD

CX5

C1

U1

R2

CX1

CX6

WDOG

U6

PHILIPS

D1

P1

X1

C2

C4

0-10V

4-20mA

THERM

R27

R31

D4

GN

D

24VA

C

TB1

D5

C1

1

U12

LED 2

POWER

V1

R25

R26

C7

CX15

CX13

PROC.

DRIVER

LOOP

DRIVER

LOCAL

LOOP

GN

D

AIN

2

AIN

1

+5V

TB2

P4

OFF=0-5V

AIN2

AIN1

0-10V

4-20mA

THERM

TB3

U15

LD5

LD6

U13

C8

LED 1

RV

1

R4

VR

EF

CX

2

U1

1

YS101900PMINILINK

POLLING

DEVICE

REV

. 1

OFF

1

2

4

8

16

32

CX14

NETWORK

DRIVER

RN3

SH

LD

SHLD

T

T

TB4

R

R

U14

NETWORK

LOOP

P5

AD

D

P3

R24

LD4

C9

U10

RN2

SW1

R30

X2

R29

R28

C10

U6

CX6

CX

1

U7

U1

X1

C3

C1

R3

CX7

Network

Network

Local

Local

24 V

A

C

(6 V

A

)

24 V

A

C

(6 V

A

)

MiniLink PD Loop 1

MiniLink PD Loop 2

Line V

oltage

V

A

V/Zone

Controller

Connect

T

o

Next

V

A

V/Zone Controller

On Branch Circuit

SHLD

T

R

T

ypical T

erminal Blocks.

All

W

iring T

o

Be T T

o

T

, SHLD (G)

T

o

SHLD (G) & R T

o

R

T

G

R

485 LOOP

FILENAME

DESCRIPTION:

P

AGE

JOB NAME

1 of 2

T

yp. Multiple Loop Networked System W

ith Modular V

A

V/Zone Controllers

Power/Comm

Board

Line V

oltage

24 V

AC - Size

T

ransformer

For Required V

A

Load

TB1

Connect

T

o

Modular

I/O Connectors

Located On Back

Of

The System Manager

ENTER

CLEAR

ESC

PREV

NEXT

DOWN

UP

6

5

4

DEC

7

0

8

13

2

9

MINUS

-

ST

A

TUS

SE

TPOINTS

SCHEDULES

AL

ARMS

OVERRIDES

Modular System Manager SD

TB2

VAC

F1

25

4A

24

SHLD

T

R

POWER

LD1

TB1

C1

POWER & COMM
DIST. BOARD
YS101856
REV. 0

P5

P4

P3

P1

D1

V1

R1

P2

COMMP

IN

POWER & COMM

OUT

Connect T

o

Other V

A

V/Zone

Controllers

On Loop

Connect T

o

Other V

A

V/Zone

Controllers

On Loop

Connect T

o

Other V

A

V/Zone

Controllers

On Loop

Power/Comm

Board

V

A

V/Zone

Controller

Line V

oltage

24 V

AC - Size

T

ransformer

For Required V

A

Load

Note:

A

Maximum Of 6 V

A

V/Zone Controllers

Can Be Connected

T

o

Each Branch Circuit.

A

total

Of 16 Controllers

Are

Allowed Per Power/Comm

Board. Use

Additional Power/Comm Boards For

Systems

That Exceed 16 Controllers. See

The

V

A

V/Zone Controller Wiring Diagram For

Power/Comm Board

T

ransformer Sizing

And

Circuit Design Information.

TB2

VAC

F1

25

4A

24

SHLD

T

R

POWER

LD1

TB1

C1

POWER & COMM
DIST. BOARD
YS101856
REV. 0

P5

P4

P3

P1

D1

V1

R1

P2

COMMP

IN

POWER & COMM

OUT

Connect T

o

Loop 2

Power/Comm

Board & VCM-X

Controller

Connect To Loop 3

MiniLink PD

Wiring & Connection Diagram

O-VCMX-Net-MultiLoop-1A.CDR

Networked System - Multiple Loop

Line V

oltage

24 V

A

C

(8 V

A

)

WARNING

OBSERVE
POLARITY

1

0

OE282

PO

WER

/

CO

O

MM

REC

www.orioncontrols.com

OE744-31-VAVZ

P.I. VAV/ZONE

CONTROLLER ACTUATOR

PACKAGE

1

0

OE282

PO

WE

R
/

CO

O

MM

REC

www.orioncontrols.com

OE744-31-VAVZ

P.I. VAV/ZONE

CONTROLLER ACTUATOR

PACKAGE

1

10 V

AC T

o

24 V

A

C

Power Pack

Note:

CommLink Must Be Set

For Multiple Loop Operation

VCM-X E-BUS

Controller

Modular Service

T

ool SD

Back V

iew of CommLink 5

Front V

iew of CommLink 5

Serial #

COMPUTER

USB

10/100

ETHERNET

DIAG

485 LOOP

POWER

ACT

LNK

HIGH

LOW

BAUD

R(

+)

24V

GND

SHLD

T(

-)

MULT

IPLE

SINGLE

LOOP

Note:

Either

A

Modular System Manager SD,

System Manager

TS II, Modular Service

T

ool

SD Or PC With Prism 2 Software Installed Can

Be Used

T

o

Program

And Configure

The Orion

System. For Computer & IP

Module

Connection Information See

The Computer

Connection Section Of

This Manual.

05/07/15

S. Olson

BY

:

DA

TE:

Figure 10: Networked Multiple Loop System Wiring With Modular VAV/Zone Controllers