Stand alone system, Vcm-x component & systems wiring 22, Zone – Orion System VCM-X E-BUS Component User Manual

Page 22: Typical stand alone system

Advertising
background image

Zone

Zone

Stand Alone System

VCM-X Component & Systems Wiring

22

FILENAME

DESCRIPTION:

P

AGE

Wiring & Connection Diagram

JOB NAME

O-VCMX-Sys-Stand-Alone-1A.CDR

VCM-X E-BUS Stand

Alone System

1 of 1

T

ypical Stand

Alone System

Connect

T

o

Modular

I/O Connectors

Located On Back

Of

The System Manager

Connect MIni Din

Connector Cable Ends

T

o

Female Connectors

on Modular Service

T

ool

And VCM-X

Controller

ENTER

CLEAR

ESC

PREV

NEXT

DOWN

UP

6

5

4

DEC

7

0

8

13

2

9

MINUS

-

ST

A

T

US

SE

TPOINTS

SCHEDULES

AL

ARMS

OVERRIDES

Line V

oltage

Modular Service

T

ool SD

Modular System Manager SD

(Front Side Shown)

System Manager TS II

(Back Side Shown)

24 V

A

C

(6 V

A

)

Note:

Either

A

Modular System Manager SD, System Manager

TS II, Modular Service

T

ool SD Or PC With Prism 2 Software

Installed Can Be Used

T

o

Program

And Configure

The Orion

System. For Computer Connection Information, See

The

Computer

And Remote Connection Section Of

This Manual.

Line V

oltage

VCM-X Unit

Controller

24 V

A

C

(8 V

A

)

SHLD

T

R

T

ypical T

erminal Blocks.

All

W

iring T

o

Be T T

o

T

, SHLD (G)

T

o

SHLD (G) & R T

o

R

T

G

R

485 LOOP

WARNING

OBSERVE
POLARITY

RS

T

+

BLACK (R)

Connect T

o

T

, R & S

T

erminals On

VCM-X

Controller

RED (24 VAC)

BROWN (GND)

WHITE (T)

BARE (S)

.1uF

YS102178 R4

WQVGA

G

raphical Interface

W

a

ttMaster Controls, Inc

C24

R9

R7

R6

R5

R2

R1

C51

C39

C20

C19

C15

C14

C13

C12

C11

C10

C9

C7

C1

X3

8.

00
Mh

z

OFF

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

1002

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

.1uF

1002

.1uF

1002

1002

.1uF

.1uF

.1uF

.1uF

L

T

C3824

1002

1002

1002

1002

1002

1002

66.000Mhz

MADE IN USA

330uF 50V

330uF

1002

SERIAL

#

OPT

4

OPT

3

OPT

2

OPT

1

TERM

RT

C

YS102178 R4

WQVGA

G

raphical Interface

W

a

ttMaster Controls, Inc

CAL

5V

3.3V

2.5V

J3

R34

R16

R13

R8

R39

X2

R26

R17

R14

C24

U13

R49

R48

R47R46

R45

R44

R43

R40

R37

R35

R32

R31

R29

R27

R24

R22

R12

R1

1

R10

R9

R7

R6

R5

R2

R1

L5

L4

D12

D11

D1

C51

C50

C45

C41

C39

C36

C20

C19

C18

C17

C16

C15

C14

C13

C12

C11

C10

C9

C8

C7

C6

C5

C4

C1

J1

R41

C23

C25

C26

R42

X3

R20

C27

C34

C

40

U10

U1

1

C28

C29

R18

C35

D2

L1

R25

C31

R19

U9

R28

C32

R30
R33

C30

R15

Q2

R21

R23

SW1

C2

C3

V1

R36

1002

RS

T

+

1002

R

T

5V

GND

TERM

For Stand

Alone

Applications

Both Jumpers Must Be ON

WHITE (T)

DRAIN WIRE (SHLD)

BLACK (R)

RED (24 V

AC)

Line V

oltage

24 V

A

C

(6 V

A

)

CLEAR (GND)

GREEN (GND)

BY

:

S. Olson

DA

TE:

05/12/15

Figure 3: Stand Alone System Wiring