Verilink APS 2000 T1 Line Protection (880-502411-001) Product Manual User Manual

Page 16

Advertising
background image

Overview

1-8

Verilink APS 2000 User Manual

Each CSU can be configured for the desired mode of operation. The
configuration data is stored in each module and can be retrieved or
edited.

Network

Management

The Access System 2000 performs the following network
management-related functions:

Performance Data

Generates and stores T1 circuit performance data. An operator can
retrieve this data for circuit analysis and maintenance.

Generates non-service-affecting T1 performance data required
by AT&T TR-54016 and ANSI T1M1.3.

Generates non-service-affecting performance report messages
consistent with ANSI T1.403-1989.

Network Transmission Functions

The CSU performs network transmission functions such as:

• T1 signal framing and encoding

• Line coding conversion

• Network density enforcement

• Performance data processing and storage

• CSU status and alarm reporting

• T1 test signals and loopbacks for circuit diagnostics and

maintenance

Circuit

Maintenance

Access System 2000 equipment provides several built-in features
that make circuit maintenance, diagnostics, and testing possible:

Loopbacks

Four different signal loopbacks are available for rapid T1 circuit
trouble isolation. Each of these loopbacks can be activated or
deactivated by an operator.

Test signals

Each CSU is capable of applying one of four test signals to the
circuit through operator-issued commands.

Service-affecting diagnostics, testing, and maintenance in
accordance with AT&T Publication 54016.

Advertising