Specifications, Scc 2120 and tac 2110, Appendix a – Verilink APS 2000 T1 Line Protection (880-502411-001) Product Manual User Manual

Page 79: Appendix

Advertising
background image

Verilink APS 2000 User Manual

-1

Appendix

A

Specifications

SCC 2120 and TAC 2110

Interfaces

DS-1 Equipment

Network

Line Rate

1.544 Mbps

±

32 ppm

1.544 Mbps

±

32 ppm

Line Code

AMI, B8ZS

AMI, B8ZS

Framing Formats

Unframed, SF, ESF

Unframed, SF, ESF

Impedance

100 ohms

±

5%

100 ohms

±

5%

Input Level

3.0 V

±

0.3 V base-to-peak, attenuated by

up to 655 feet of cabling

DS-1 attenuated by 0 to 27.5 dB

Pulse Width

324

±

45 nanoseconds at half amplitude

324

±

45 nanoseconds at half amplitude

Pulse Afterkick

10% to 30% of pulse peak

10% to 30% of pulse peak

Output Level

DSX-1 into 100 Ohms

3.0 V

±

0.3 V base-to-peak

Output LBO

N/A

0, 7.5, or 15 dB (0 to 3000 feet), selectable

Pulse Density

Enforcement

N/A

12.5% average density and 80 zeros, AT&T
62411, 15 zeros, 80 zeros, or none

Pre-equalization

0 to 655 feet, selectable

N/A

Surge Protection

Up to 400 Vp-p

Up to 400 Vp-p

Loopbacks

Equipment (ELB

Controlled via ESF Data Link

Repeater (RLB)

Controlled via ESF Data Link

Line (LLB)

Controlled via in-band codes, or TABS or ANSI
T1.403 commands on the ESF Data Link

Payload (PLB)

Controlled via TABS or ANSI T1.403 commands on
the ESF Data Link

All loopbacks are accessible via the ASCII terminal.

Alarm rela

Contacts Provided

Normally open, normally closed and common lead

Configuration

Form C

Contact Rating

1A at 52 V

dc

or 2A at 26 V

dc

, non-inductive

Closure Conditions

SCC/CSU hardware failure
LOS from network or DS-1 equipment
Loss of synchronization from network
Loss of synchronization from equipment
Loopback in progress
Loss of power
Removal of CSU from shelf
LOF
Excessive BER
Excessive BPV (>10

-4

)