Connecting the CIMs

After installing the CSUs into the shelves, connect each module to
the external customer premise equipment. These connections are
made at the associated CIM 2022 APS or CIM 2010 APS in back of
the shelf.

Figure 2-2 Rear view of CIM interconnections

Ethernet adapter

9-pin

To

(10BaseT and 10Base2

connector

REV *

EQ

P

T

E

T

HE

RNE

T

EX

T T

IM

IN

G

SL

IP

NE

T

W

ORK

CIM

2022

REV *

EQ

PT

EX

T T

IM

IN

G

N

E

T

W

O

R

K

CIM

2010

SLIP connection

Ethernet

T1 Protection Line (P1)

T1 Line (L2)

Slot 1

Slot 2

connections)

Installing the Protection Line (Slot 1):

1.

Plug the T1 protection line (P1) into the

Network Port of the CIM 2022 APS in Slot

1.

2.

Run an RJ-48 cable from the

EQPT

Port of

the CIM 2022 APS to its APS IN port.

3.

Connect the APS CIMs in your shelf by

cabling the APS OUT port on the Slot 1

CIM to the APS IN port on the next APS

CIM. Continue daisy-chaining APS OUT

ports to APS IN ports for all the TACs on

your shelf. Leave the APS OUT port on the

lowest priority CIM empty.

NOTE: Both ends of the T1 protection group
must have the same priority cabling
sequence.

Making the network management connections

1.

Use

Management Port (IN) for SLIP con-

nection.

2.

Use the

Management Extension

port for

Ethernet connection.

3.

Use the Craft interface to configure IP

addresses.

To

SLIP peer

AP

S

OUT

AP

S

I

N

A

PS O

U

T

APS

APS

APS priority

cables

To Low Priority CPE

part numbe

458-502572-001