System shelves and heat baffles – Verilink APS 2000 T1 Line Protection (880-502411-001) Product Manual User Manual

Page 80

Advertising
background image

-2

Verilink APS 2000 User Manual

System shelves and heat baffles

Test patterns

Outputs

Quasi-random signal sequence (QRSS)
1-in-8
3-in-24
511

Timing and external

clocks

Timing Mode

Through (recovered from input — both directions)

Power Requirements

Inputs

+5.5 V

dc

1%; - 12.5 V

dc

±3%

Current Requirements

900 mA at +5.5V; 30 mA at -12.5V (nominal)

Environment

Operating Temperature

32

°

F (0

°

C) to 122

°

F (50

°

C)

Storage Temperature

-4

°

F (-20

°

C) to 167

°

F (75

°

C)

Humidity

5% to 95%, non-condensing

Interface modules

SCC 212

CIM 2022 APS (RJ-48C connectors)

TAC 2110

CIM 2010 APS (RJ-48C connectors)

Dimensions

CSUs

8.1 in. (20.2 cm) high x 8.3 in. (21 cm) deep x 0.96 in.
(2.5 cm) wide

CIMs

8.5 in. (21.8 cm) high x 2.9 in. (7.5 cm) deep x 0.96 in.
(2.5 cm) wide

Regulatory and technical

compliance

AT&T 54016
AT&T 62411
ANSI T1.403
FCC Part 68
UL 1459 Revision 2

MLS 2200

Height

8.75 in. (22.2 cm)

(Multi-line shelf)

Width

17.25 in. (44.2 cm)
[19 in. or 23 in. with brackets]

Depth

10.50 in. (26.7 cm)

Weight

14 lb. (6.35 kg), empty

Operating Temperature

32

°

F (0

°

C) to 122

°

F (50

°

C)

Storage Temperature

14

°

F (-10

°

C) to 185

°

F (85

°

C)

Humidity

5% to 95% relative humidity, non-condensing

Power Dissipation

34 W (116 BTU), fully equipped, maximum

Cooling

Free air circulation

Power supply inputs

PAC 2910 or PDC 2920 — +5.5 Vdc and -12 Vdc

Regulatory And

Technical Compliance

UL 1459 Rev. 2, FCC Part 15 (Class A), FCC Part 68

Advertising