Verilink APS 2000 T1 Line Protection (880-502411-001) Product Manual User Manual

Page 26

Advertising
background image

Quick Setup

2-2

Verilink APS 2000 User Manual

d. No flow control (both hardware flow control and X-on/X-off

flow control must be disabled).

8. Press the E

NTER

key. The prompt pSH+> is displayed.

9. Log on to the ASCII interface by typing "craft" at the pSH+>

prompt and pressing E

NTER

to get the YOUR PASSWORD?

prompt. If you’re accessing the node for the first time, press
E

NTER

(initially there is no password). The SCC 2120 Main

Menu is displayed.

10. Use the "O" command to access the Administration Menu.

11. Use the "E" command to access the Ethernet Configuration

submenu.

12. Set the node’s Ethernet IP address, and subnet mask as

required for your local LAN segment. Use Ethernet/DIX for the
Ethernet type. Return to the Administration Menu using the
"X" command.

13. Reboot the SCC 2120 using the "B" command. Then repeat

steps 8 and 9 to return to the Main Menu.

14. Use the "C" command to access the Configuration Menu.

15. Use the "W" command to set the correct framing type for your

DSX-1 equipment (first of two choices) and T1 facility (second
choice). For this example we will assume you wish to connect a
D4/AMI PBX port to an ESF/B8ZS line. Select 3(SF,ESF).

16. Use the "F" command to select the format (line coding), for this

example select 2(AMI,B8ZS).

17. Document your installation, you may use the worksheet in

Figure 2-1

.

18. Perform the initialization procedure described in

Initializing

the APS 2000

in Chapter 3.

Advertising