Verilink APS 2000 T1 Line Protection (880-502411-001) Product Manual User Manual
Page 72

Diagnostics
5-8
Verilink APS 2000 User Manual
Table 5-3 SCC 2120 and TAC 2110 Bantam Jacks
Figure 5-5 SCC and TAC Signal Access Jacks
Label
Function
EQPT IN jack
The
EQPT IN
jack breaks the transmission path toward
the DS-1 equipment. This allows an operator to apply an
external test signal to the equipment receiver.
EQPT OUT jack
The
EQPT OUT
jack breaks the transmission path
toward the network and looks toward the DS-1
equipment transmitter. This jack can be patched to the
test set receiver for signal measurement.
NET IN jack
The
NET IN
jack looks toward the network when
accessed. It can be patched to the test set transmitter
for test signal application to the network.
NET OUT jack
The
NET OUT
jack permits external measurement of
the incoming signal from the network.
MON jacks
The
MON
jacks are non-intrusive. When accessed, each
jack permits signal monitoring by an external test set
without interrupting normal transmission.
SCC 2120 or TAC 2110
EQPT
EQPT
NET
LBO
OUT
IN
EQPT
IN
NET
OUT
NET
MON
Repeater
Surge
Protect
Surge
Protect
Part of
CIM 2024 or
CIM 2010
To/From
Network
To/From
DS- 1
Equipment
Part of
CIM 2024 or
CIM 2010
MON