Important do’s and don’ts, Firmware upgrade procedures, Upgrading scc modules – Verilink APS 2000 T1 Line Protection (880-502411-001) Product Manual User Manual

Page 48: Important do’s and don’ts -20, Firmware upgrade procedures -20, Upgrading scc modules -20

Advertising
background image

Configuration

3-20

Verilink APS 2000 User Manual

Important Do’s

and Don’ts

1. If you’re in Telnet, exit from the Craft screens until the pSH+>

prompt is reached before disconnecting the Telnet session.

2. There is only one possible Trap Host IP address. You must use

the Trap Host IP address as the SLIP Peer IP address.

Firmware Upgrade Procedures

Firmware upgrades performed using an SCC 2120 may be divided
into two categories: upgrades of the SCC module’s own firmware,
and upgrades in which the SCC broadcasts new firmware to the TAC
2110 module(s) in the node.

Upgrading SCC

Modules

The two procedures below are used to upgrade the firmware of an
SCC 2120. In each case you must be running from the opposite
flashbank. To upgrade flashbank A, you must be running from
flashbank B. To upgrade flashbank B, you must be running from
flashbank A.

To use these

procedures you

will need

A file containing a new revision of SCC firmware.

An Ethernet or SLIP connection to the SCC 2120 (for
performing FTP file transfers).

a Telnet application or a direct terminal connection to the SCC
Craft interface.

An FTP server application.

NOTE: Most common FTP programs are CLIENTS, not SERVERS. Be

sure you have an FTP server program. Such programs, often

distributed as shareware, may be found on World Wide Web

download sites.

To use these

procedures you

will need to know

Basic TCP/IP terminology.

How to use FTP.

How to use the specific FTP server program you have selected.

The IP address of the FTP server.

The specific path and filename to the new SCC firmware file.

Before beginning

this upgrade

1. If need be, install the FTP server program which you have

selected.

Advertising