Performance Monitoring

Verilink APS 2000 User Manual

4-11

Severely Errored

Framing Second

(SEFS)

An SEFS is a second experiencing one or more events of two or
more frame bit errors in a 3-millisecond period.

Loss of Signal

Second (LOSS)

An LOSS is a second in which an LOS condition exists.

Alarm Indication

Signal Second

(AISS)

An AISS is a second in which the CSU receives an AIS from the
network.

Remote Alarm

Indication Second

(RAIS)

This is a second during which the CSU detects an RAI (Yellow
Alarm) from the network.

Bit Error Rate

Alarm Second

(BERS)

This is a count of each second during which a network BER alarm
condition existed.

Loss of frame

Second (LOFS)

An LOFS is a count of each second in which the CSU was in a LOF
state.

Out-of-Frame

Second (OOFS)

An OOFS is a second experiencing one or more OOF events.

Equipment Low-

Density Second

(DTED)

This is a second during which a low-density state occurs and the
CSU stuffs a ONE into the signal from the equipment to maintain
minimum ONEs density on the DS-1 network. The CSU also records
a DTED whenever it applies a keep-alive signal to the network.

Equipment Bit

Error Rate Alarm

Second (DBER)

This is a second during which the incoming bit error rate from the
equipment exceeds the operator-defined threshold.

Equipment Errored

Second

This is the same as the ES previously described, except that it is
detected on the incoming signal from the DS-1 equipment.

Equipment UAS,

ES-L, and OOFS

These are the same as the UAS, ES-L, and OOFS previously
described, except that they are detected on the incoming signal
from the DS-1 equipment.

Performance

data processing

The CSU circuits store and process the DS-1 performance data
described above in three stages, or strata. The following sections