Verilink APS 2000 T1 Line Protection (880-502411-001) Product Manual User Manual

Page 42

Advertising
background image

Configuration

3-14

Verilink APS 2000 User Manual

M) distance

Cable length option,

used to increase DSX-

1 signal strength

when DSX-1 cable is

long.

Choices are: (1)0-133 (2)133-266 (3)266-399 (4)399-533

(5)533-655, select the value that most nearly equals the

length of the cable between the CSU and the local DSX-1

equipment.

L) lbO

Line build out is used

to reduce the signal

strength being sent

to the T1 network.

New T1 circuits

installed by a

telephone company

in the USA will have a

smart jack, use 0db.

(1) 0 db — use this value if a smart jack (network

termination device) has been installed by the telephone

carrier, or if the first active device on the T1 is between

2,000 and 3,000 feet away.

(2) 7.5 db — use this value only if there is no smart jack and

the first repeater is 1,000 to 2,000 feet away.

(3) 15 db — use this value only if there is no smart jack and

the first repeater is zero to 1,000 feet away.

K) aps control

Selects the mode for

the Automatic

Protection Switch

function.

See the section "

"APS Control Modes""

below.

T) alm thld

Selects enabling or

disabling thresholds.

(1)disable — Alarm threshold function is shut off.

(2)default — Default values for alarm thresholds are

enabled.

Z) density

Selects density

enforcement

technique.

Density should

always be set to

NONE on a B8ZS T1,

B8ZS allows a full

64K per DS0.

Density should never

be set to NONE on an

AMI T1.

(1)NONE — no density enforcement, use this value only and

always on a B8ZS T1.

(2)12 — The CSU begins stuffing ones into the user

datastream after 12 consecutive zeroes.

(3)62411— The CSU enforces AT&T publication 62411

density restrictions (average 12.5% minimum ones density).

(4)80 0's — The CSU begins stuffing ones into the user

datastream after 80 consecutive zeroes (recommended).

(5)15 0's — The CSU begins stuffing ones into the user

datastream after 15 consecutive zeroes.

C1-C5) canned

config

Allows selection of

any of five complete

configurations which

vary according to

framing and line

coding on Equipment

and Network sides.

Canned configuration #1, EQPT=SF/AMI NET=ESF/AMI.

Canned configuration #2, EQPT=ESF/AMI NET=ESF/AMI.

Canned configuration #3, EQPT=SF/AMI NET=ESF/B8ZS.

Canned configuration #4, EQPT=SF/B8ZS NET=ESF/B8ZS.

Canned configuration #5, EQPT=ESF/B8ZS NET=ESF/B8ZS.

Menu Option

Description

Instructions

Advertising