Grass Valley NV9000-SE v.5.0 User Manual
Page 331

313
NV9000-SE Utilities
User’s Guide
Configuration Page for LCD XY/MD Mode
This is a sample NV9648 panel configuration page for XY/MD mode:
The panel in LCD XY/MD mode has a more extensive function set than panels in client mode or
standalone mode. In LCD XY/MD mode too, the panel does not require the presence of an
NV9649.
The panel’s 3 sections are not independent control units, but integrated into a single larger
control unit. The 3 displays together show the current source, the preset source, and the current
destination. All 27 function buttons form a “button page” in a hierarchical structure of button
pages.
The panel’s buttons can be used in a hierarchical fashion: pressing a ‘navigation’ button causes
the panel to display a new set of configured button functions, called a “button page.” There can
be many such pages, organized in a configurable tree structure.
Button
Definition
Section
Page
Table
Panel
Options
Panel Image:
GPIO Defi-
nitions