Scanner instruction manual, Display parameter action/setting description – Precision Digital PD6080 User Manual

Page 27

Advertising
background image

PD6080/PD6081 Super Snooper Modbus

Scanner Instruction Manual

27

Display

Parameter

Action/Setting Description

float

Floating Point Data Type

Floating Point Data Type. Select Floating Point as the data type to be
read from the slave device.

short

Short Integer Data Type

Short Integer Data Type. Select Short Integer as the data type to be
read from the slave device.

long

Long Integer Data Type

Long Integer Data Type. Select Long Integer as the data type to be
read from the slave device.

binary

Binary

Binary Data. Select Binary format for Short or Long integers.

bcd

BCD

BCD Data. Select BCD format for Short or Long integers.

signed

Signed

Signed Data. Select Signed Binary format for Short or Long integers.

unsigd

Unsigned

Unsigned Data. Select Unsigned Binary format for Short or Long
integers.

1234

Byte Order

Select big-endian byte order.

4321

Byte Order

Select little-endian byte order.

2413

Byte Order

Select byte-swapped big-endian byte order. Not available for Short.

3412

Byte Order

Select byte-swapped little-endian byte order. Not available for Short.

t-resp

Response Time

Enter the time allowed for a slave device to respond to a command.

slave

Slave

Enter Slave Mode

data

Data Type

Enter the Data Type for each PV

float

Floating Point Data Type

Floating Point Data Type. Select Floating Point as the data type to be
read from the slave device.

short

Short Integer Data Type

Short Integer Data Type. Select Short Integer as the data type to be
read from the slave device.

long

Long Integer Data Type

Long Integer Data Type. Select Long Integer as the data type to be
read from the slave device.

binary

Binary

Binary Data. Select Binary format for Short or Long integers.

bcd

BCD

BCD Data. Select BCD format for Short or Long integers.

signed

Signed

Signed Data. Select Signed Binary format for Short or Long integers.

unsigd

Unsigned

Unsigned Data. Select Unsigned Binary format for Short or Long
integers.

1234

Byte Order

Select big-endian byte order.

4321

Byte Order

Select little-endian byte order.

2413

Byte Order

Select byte-swapped big-endian byte order. Not available for Short
integer.

3412

Byte Order

Select byte-swapped little-endian byte order. Not available for Short
integer.

t-resp

Response Time

Enter the time allowed for a slave device to respond to a command.

setup

Setup

Enter Setup menu

pv

Process Variable

Enter PV Setup menu

Pv 1

PV

Select PV 1-16

tag

Tag

Tag

units

Units

Units

formt

Format

Format (Decimal, Eighths, or Sixteenths of an Inch)

dec

Decimal

Decimal Format

Ft In 8

Eighths

Eighth Inch Format

Ft In 16

Sixteenths

Sixteenth Inch Format

Dec.Pt

Decimal Point

Decimal Point menu

Disp.dp

Display Decimal Point

Set the decimal point position for the display. This is independent from
float decimal point.

Advertising