PD6080/PD6081 Super Snooper Modbus

Scanner Instruction Manual

90

Analog Output Source Programming (aoutpr)

The 4-20 mA analog outputs can be programmed for source of data, overrange and underrange, absolute
maximum and minimum output, and communications break values. They can also be recalibrated.

Underrange

Max

Min

All enabled

PVs 1-16 & all
Set Points 1-8

To

RUN

Mode


• To calibrate the analog outputs, follow the graphic above.
• The overrange and underrange values are the values that will be output when the display shows an

overrange or underrange condition. This setting is common to all analog outputs.

• The maximum and minimum values are the absolute limits for the 4-20 mA output. This setting is

common to all analog outputs.

• The communications break value determines the mA output when a Slave fails to reply to a command

within the Response time.