Avago Technologies LSI53C895A User Manual

Page 159

Advertising
background image

SCSI Registers

4-51

A phase mismatch (initiator mode) or SATN/ becomes
active (target mode)

An arbitration sequence completes

A selection or reselection time-out occurs

The LSI53C895A is selected

The LSI53C895A is reselected

A SCSI gross error occurs

An unexpected disconnect occurs

A SCSI reset occurs

A parity error is detected

The handshake-to-handshake timer is expired

The general purpose timer is expired

A SCSI bus mode change is detected

To determine exactly which condition(s) caused the
interrupt, read the

SCSI Interrupt Status Zero (SIST0)

and

SCSI Interrupt Status One (SIST1)

registers.

DIP

DMA Interrupt Pending

0

This status bit is set when an interrupt condition is
detected in the DMA portion of the LSI53C895A. The
following conditions cause a DMA interrupt to occur:

A PCI parity error is detected

A bus fault is detected

An abort condition is detected

A SCRIPTS instruction is executed in single step
mode

A SCRIPTS interrupt instruction is executed

An illegal instruction is detected

To determine exactly which condition(s) caused the
interrupt, read the

DMA Status (DSTAT)

register.

Advertising