Table 6.12 output signal – serr, Output signal – serr, Table 6.12 – Avago Technologies LSI53C896 User Manual
Page 275
Advertising

DC Characteristics
6-7
Version 3.3
Copyright © 1998–2003 by LSI Logic Corporation. All rights reserved.
Table 6.11
Output Signals – INTA, INTB, ALT_INTA, ALT_INTB, REQ/
Symbol
Parameter
Min
Max
Unit
Test Conditions
V
OH
Output high voltage
0.9 V
DD
–
V
−
500
µ
A
V
OL
Output low voltage
–
0.1 V
DD
V
1500
µ
A
V
OH
5 V Tolerant output high voltage
2.4
–
V
−
16 mA
V
OL
5 V Tolerant output low voltage
–
0.55
V
16 mA
I
OZ
3-state leakage
−
10
10
µ
A
V
PIN
= 0 V, 5.25 V
I
PULL-UP
Pull-up current
1
−
75
−
7.5
µ
A
–
1. Pull-up test does not apply to REQ/.
Table 6.12
Output Signal – SERR/
Symbol
Parameter
Min
Max
Unit
Test Conditions
V
OL
Output low voltage
–
0.1 V
DD
V
1.5 mA
I
OZ
3-state leakage
−
10
10
µ
A
–
Advertising