Auto fill #pts, Auto fill – HP 8360 User Manual

Page 169

Advertising
background image

Auto Fill

Function Group

FREQUENCY, POWER

Menu Map

Description

This

is used in two locations:

Menu and

List Menu.

Flatness Menu When selected, the synthesizer waits for a numeric
value representing the number of correction points to be entered.
Number of Correction Points: is displayed in the active entry area.
A list of frequencies containing the number of specified points is
created automatically. The list begins at the auto fill start frequency
and ends at the auto fill stop frequency. The rest of the points are
equally spaced between them. A minimum of two points must be
entered.

If the number of points requested creates a list that exceeds the
number of elements available

the following message appears:

TOO MANY CORRECTION PTS

List Menu When selected, the synthesizer waits for a numeric value
representing the number of list points to be entered.

Number

of List Frequencies: is displayed in the active entry area. A list
of frequencies containing the number of specified points is created
automatically. The list begins at the auto fill start frequency and

ends at the auto fill stop frequency. The rest of the points are equally
spaced between them. A minimum of two points must be entered.

If the number of points requested creates a list that exceeds the
number of points available

the following message appears:

Error. . . t o o m a n y l i s t p o i n t s r e q u e s t e d .
P o i n t s u s e d : 0
P o i n t s a v a i l a b l e : 8 0 1

Programming Codes

SCPI:

NONE, see Fltness

or List Menu

Analyzer:

NONE

See Also

Menu,

List Menu

“Optimizing Synthesizer Performance” in Chapter 1.