IBM POWERPC 750GL User Manual

Page 73

Advertising
background image

User’s Manual

IBM PowerPC 750GX and 750GL RISC Microprocessor

gx_02.fm.(1.2)
March 27, 2006

Programming Model

Page 73 of 377

User Monitor Mode Control Register 0 (UMMCR0)

The contents of MMCR0 are reflected to UMMCR0, which can be read by user-level software. MMCR0 can
be accessed with mfspr using SPR 936.

6

DISCOUNT

Disables counting of PMCn when a performance-monitor interrupt is signaled (that is,
((PMCnINTCONTROL = '1') & (PMCn[0] = '1') & (ENINT = '1')) or when an enabled time-
base transition occurs with ((INTONBITTRANS = '1') & (ENINT = '1')).

0

Signaling a performance-monitor interrupt does not affect the counting status of
PMCn.

1

Signaling a performance-monitor interrupt prevents changing of the PMC1
counter. The PMCn counter does not change if PMC2COUNTCTL = '0'.

Because a time-base signal could have occurred along with an enabled counter overflow
condition, software should always reset INTONBITTRANS to zero, if the value in INTON-
BITTRANS was a one.

7:8

RTCSELECT

64-bit time base, bit selection enable.
00

Pick bit 63 to count.

01

Pick bit 55 to count.

10

Pick bit 51 to count.

11

Pick bit 47 to count.

9

INTONBITTRANS

Cause interrupt signaling when the bit identified in RTCSELECT transitions from off to on.
0

Do not allow interrupt signal if chosen bit transitions.

1

Signal interrupt if chosen bit transitions.

Software is responsible for setting and clearing INTONBITTRANS.

10:15

THRESHOLD

Threshold value. The 750GX supports all six bits, allowing threshold values from 0–63.
The intent of the THRESHOLD support is to characterize L1 data-cache misses.

16

PMC1INTCONTROL

Enables interrupt signaling due to PMC1 counter overflow.

0

Disable PMC1 interrupt signaling due to PMC1 counter overflow.

1

Enable PMC1 interrupt signaling due to PMC1 counter overflow.

17

PMCINTCONTROL

Enable interrupt signaling due to any PMC2–PMC4 counter overflow. Overrides the set-
ting of DISCOUNT.

0

Disable PMC2–PMC4 interrupt signaling due to PMC2–PMC4 counter overflow.

1

Enable PMC2–PMC4 interrupt signaling due to PMC2–PMC4 counter overflow.

18

PMCTRIGGER

Can be used to trigger counting of PMC2–PMC4 after PMC1 has overflowed or after a
performance-monitor interrupt is signaled.
0

Enable PMC2–PMC4 counting.

1

Disable PMC2–PMC4 counting until either PMC1[0] = 1 or a performance-moni-
tor interrupt is signaled.

19:25

PMC1SELECT

PMC1 input selector; 128 events selectable.

26:31

PMC2SELECT

PMC2 input selector; 64 events selectable.

Bits

Field Name

Description