Siemens Simatic S7-300 CPU 31xC and CPU 31x S7-300 User Manual

Page 50

Advertising
background image

Communication

3.2 Communication services

CPU 31xC and CPU 31x, Technical data

3-22

Manual, Edition 08/2004, A5E00105475-05

The following table provides you with an overview of the system and standard functions for

SIMATIC, whose functionality must be implemented by other functions when converting from

PROFIBUS DP to PROFINET IO.

Table 3-7

System and Standard Functions in PROFIBUS DP that must be Implemented with

Different Functions in PROFINET IO

Blocks

PROFINET IO

PROFIBUS DP

SFC55 (write dynamic

parameters)

No

(implement with SFB53)

Yes

SFC56 (write predefined

parameters)

No

(implement with SFB81 and

SFB53)

Yes

SFC57 (assign parameters to

module)

No

(implement with SFB81 and

SFB53)

Yes

You cannot use the following SIMATIC system and standard functions with PROFINET IO:

SFC7 (trigger hardware interrupt on DP master)

SFC11 (synchronize groups of DP slaves)

SFC12 (deactivate and activate DP slaves)

SFC72 (read data from a communication partner within local S7 station)

SFC73 (write data to a communication partner within local S7 station)

SFC74 (abort an existing connection to a communication partner within local S7 station)

Comparison of the Organization Blocks of PROFINET IO and PROFIBUS DP

Here, there are changes in OBs 83 and 86 as shown in the table below.

Table 3-8

OBs in PROFINET IO and PROFIBUS DP

Blocks

PROFINET IO

PROFIBUS DP

OB83 (removing and inserting

modules and submodules

during operation)

Also possible with an S7-300,

new error information

With an S7-300 not possible
Removing and inserting during

operation is reported by slaves

added using a GSD file by

means of a diagnostic interrupt;

in other words OB82.
With S7 slaves, OB86 is called

due to the station failure.

OB86 (rack failure)

New error information

Unchanged

Detailed Information

For detailed descriptions of the individual blocks, refer to the manual

System Software for

S7-300/400 System and Standard Functions.