3 handling with modules, 1 download of new blocks or delta downloads, 2 uploading blocks – Siemens Simatic S7-300 CPU 31xC and CPU 31x S7-300 User Manual

Page 74

Advertising
background image

Memory concept

4.2 Memory functions

CPU 31xC and CPU 31x, Technical data

4-12

Manual, Edition 08/2004, A5E00105475-05

Note
This function is only permitted when the CPU is in STOP mode. Load memory is cleared if

the load operation could not be completed due to power loss or illegal block data.

4.2.3

Handling with modules

4.2.3.1

Download of new blocks or delta downloads

There are two ways to download additional user blocks or download deltas:

Download of blocks: You already created a user program and downloaded it to the CPU

via MMC. You then want to add new blocks to the user program. In this case, you do not

need to reload the entire user program to the MMC. Rather, you can download only the

new blocks to the MMC (this reduces download times for highly complex programs).

Delta download: In this case, you only download the deltas in the blocks of your user

program. In the next step, perform a delta download of the user program, or only of

changed blocks to the MMC, using the PG/PC.

Warning
The delta download of blocks / user programs overwrites all data stored under the same

name on the MMC.

The data of dynamic blocks are transferred to RAM and activated after the block is

downloaded.

4.2.3.2

Uploading blocks

Uploading blocks

Other than download operations, an upload operation is the transfer of specific blocks or a

user program from the CPU to the PG/PC. The block content is here identical with that of the

last download to the CPU. Dynamic DBs form the exception, because their actual values are

transferred. An upload of blocks or of the user program from the CPU in STEP 7 does not

influence CPU memory.

Advertising