Analog Modules

5-14

S7-400, M7-400 Programmable Controllers Module Specifications

A5E00069467-07

Table 5-14 Analog Value Representation in Current Measuring Ranges 4 to 20 mA

System

Current Measuring Range

Dec.

Hex.

4 to 20 mA

118.515%

32767

7FFF

22.96 mA

Overflow

117.593%

32512

7F00

117.589%

32511

7EFF

22.81 mA

Overrange

27649

6C01

100.000%

27648

6C00

20 mA

75%

20736

5100

16 mA

0.003617%

1

1

4 mA +
578.7 nA

Rated range

0%

0

0

4 mA

– 1

FFFF

Underrange

– 17.593%

– 4864

ED00

1.185 mA

Underflow

v

– 17.596%

– 32767

7FFF

Analog Value Representation for Resistance-Type Sensors

Table 5-15 Analog Value Representation for Resistance-Type Sensors from 48

W

to 6 k

W

System

Resistance-Type Sensor Range

Dec.

Hex.

48

W

150

W

300

W

600

W

6 k

W

118.515%

32767

7FFF

56.89

W

177.77

W

355.54

W

711.09

W

7.11 k

W

Overflow

117.593%

32512

7F00

117.589%

32511

7EFF

56.44

W

176.38

W

352.77

W

705.53

W

7.06 k

W

Overrange

27649

6C01

100.000%

27648

6C00

48

W

150

W

300

W

600

W

6 k

W

75%

20736

5100

36

W

112.5

W

225

W

450

W

4.5 k

W

Rated

0.003617%

1

1

1.74m

W

5.43m

W

10.85m

W

21.70m

W

217.0m

W

range

0%

0

0

0

W

0

W

0

W

0

W

0

W

(negative values physically not possible)

Underrange

(

g

p y

y

p

)