3 technical specifications – Siemens Simatic S7-400 User Manual

Page 511

Advertising
background image

Interface Submodules

13-15

S7-400, M7-400 Programmable Controllers Module Specifications
A5E00069467-07

Interrupt Request

The interface submodule supplies an interrupt request (IRQa and IRQb) for each
serial port.

You can define the assignment of the interrupt requests IRQa and IRQb to the
appropriate processor interrupt requests in the BIOS Setup.

Table 13-14

Interrupt Assignments of the IF 962-COM Interface Submodule

Interrupt Source of the Interface Submodule

ISA Interrupt

COM a

IRQ a

Can be set in the BIOS

COM b

IRQ b

Can be set in the BIOS
setup

Default settings in the BIOS are: IRQ 4 for COM1 and IRQ3 for COM2.

Submodule ID

The IF 962-COM interface submodule has the submodule ID 41

H

.

13.4.3

Technical Specifications

Technical Specifications

The IF 962-COM interface submodule receives its supply voltage from the M7-400
programmable modules or from the M7-300/400 expansion modules. The current
consumption given in the technical specifications is the consumption required for
dimensioning the power supply, that is, the current consumption is referenced to
24 V in the M7-300 and to 5 V in the M7-400.

6ES7962-3AA00-0AC0

Technical Specifications

Supply voltage

Supplied from the M7-400
programmable modules or
from the M7-300/400
expansion modules

Current consumption in the
M7-300
(for dimensioning the 24 V
current supply)

0.04 A

Current consumption in the
M7-400
(for dimensioning the 5 V
current supply)

0.1 A

Submodule ID

41

H

Power losses

0.5 W

Dimensions
W x H x D (mm)

18.2 x 67 x 97

Weight

0.080 kg

Advertising
This manual is related to the following products: