Interface Submodules

13-19

S7-400, M7-400 Programmable Controllers Module Specifications
A5E00069467-07

Example of Setting an AT-Compatible I/O Address

In the following example, the I/O address 0278

H

is to be set in the BIOS setup.

Proceed as follows to do this:

1. Select the “IF Modules” page in the BIOS setup.

2. Enter the submodule receptacle number of the interface submodule in “Select

Module #”.

3. Enter the offset address for the configuration register of the interface submodule

“00

H

” at “Config.Index”.

4. Enter “FE

H

” or “02

H

at “Value”. This value is then written into the configuration

register (see also Table 13-20).

5. Press the OK button.

Addressing in the M7-300/400-Reserved I/O Address Area

Regardless of possible addresses in the AT-compatible I/O address area, the
IF 962-COM interface submodule can be addressed in this reserved address area.

The base address depends on the interface submodule slot in the expansion
module or the programmable module. See the descriptions “M7-300 Expansions”,
“M7-400 Expansions” or the description of the M7-400 programmable modules for
the slot-dependent base address of the interface submodule.

The I/O address is the sum of the base address and the offset address.

The registers and their meanings and the offset addresses are described below.

Table 13-17

Offset Address Assignments for the IF 962-LPT Interface Submodule

Offset

Address

Function

Remarks

00

H

Configuration register

Read/write

10

H

- 17

H

UART 16C552 parallel port

Read/write