A-11 – Siemens Simatic S7-400 User Manual

Page 573

Advertising
background image

Parameter Sets for Signal Modules

A-11

S7-400, M7-400 Programmable Controllers Module Specifications
A5E00069467-07

Structure of Data Record 1

The figure below shows the structure of data record 1 for the parameters of the
analog input modules.

You enable a parameter by setting the corresponding bit to “1”.

Byte 0

7 6

0

Diagnostic interrupt enable

Hardware interrupt enable

Upper limit value
for channel 15

Lower limit value for
channel 15

Low-Order Byte

Low-Order Byte

High-Order Byte

High-Order Byte

Byte 63
Byte 64
Byte 65
Byte 66

Upper limit value
for channel 0

Lower limit value for
channel 0

Upper limit value for
channel 7

Lower limit value
for channel 7

Low-Order Byte

Low-Order Byte

Low-Order Byte

Low-Order Byte

High-Order Byte

High-Order Byte

High-Order Byte

High-Order Byte

Byte 3
Byte 4
Byte 5
Byte 6

Byte 31
Byte 32
Byte 33
Byte 34

Byte 1
Byte 2

Reference temperature
in 0.01



C

Low-Order Byte

High-Order Byte

Figure A-5

Data Record 1 for Parameters of the Analog Input Modules

Note

The representation of the limit values and the reference temperature corresponds
to the analog value representation (see Chapter 6). Please observe the range
limits when setting the limit values.