Parameter Sets for Signal Modules

A-8

S7-400, M7-400 Programmable Controllers Module Specifications

A5E00069467-07

Structure of Data Record 1

The figure below shows the structure of data record 1 (bytes 0, 1 and 2) for the
parameters of the digital output modules.

You enable a parameter by setting the corresponding bit to “1”.

Byte 0

7 6

0

Diagnostic interrupt enable

Reaction to CPU STOP

Byte 1

7 6

0

5 4 3 2 1

Byte 2

7 6

0

Enable substitute value 1 on channel 15

5 4 3 2 1

Substitute value

Substitute value

Enable substitute value 1 on channel 7

Enable substitute value 1 on channel 6

Enable substitute value 1 on channel 5

Enable substitute value 1 on channel 4

Enable substitute value 1 on channel 3

Enable substitute value 1 on channel 2

Enable substitute value 1 on channel 1

Enable substitute value 1 on channel 0

Enable substitute value 1 on channel 8

Enable substitute value 1 on channel 9

Enable substitute value 1 on channel 10

Enable substitute value 1 on channel 11

Enable substitute value 1 on channel 12

Enable substitute value 1 on channel 13

Enable substitute value 1 on channel 14

Figure A-3

Data Record 1 for Parameters of the Digital Output Modules