Safety Instructions

Read this operation manual carefully and familiarize yourself with the operation of the drive be-

fore installation, connection (wiring), operation or maintenance and inspection of the device. Be

familiar with the drive, safety information, and safety signs before using the drive.
In this instruction manual, safety signs are classified into the following categories.

!

WARNING

Improper operation may result in death of serious injury.

!

CAUTION

Improper operation may result in slight to medium injury or property damage.

Note: More serious situations than those covered by the CAUTION sign can result depending on
the circumstances. It is important that you always follow the instructions

Compliance with UL/cUL standards [Applicable to products with UL/cUL mark]

!

CAUTION

1. [WARNING] Take care of electric shock. Be sure to turn the drive off before starting work.
2. [CAUTION] When the charge lamp is lit, the drive is still charged at a dangerous voltage.
3. [WARNING] There are two or more live parts inside the drive.
4. The drive is approved as a part used inside a panel. Install it inside a panel.
5. Perform wiring to the input, output and control terminals of the drive, referring to the table below.

Use UL certified round crimp terminal to the input and output terminals with insulation cover or
covered with reduced tube to obtain the insulation distance. Use a crimping tool recommended
by the terminal manufacturer when fabricating crimp terminals.

6. Install a fuse in the power supply to the drive, referring to the table below.











1) Only the L1/L and L2/N phases are provided for the single-phase 230V input series.
2) Use copper wires of allowable maximum temperature 60 or 75 °C.
3) Use UL certified "fast acting fuse."

Connect the power supply satisfying the characteristics shown in the table below as an input power supply
of the drive. (Short circuit rating)

Tightening torque

Lb • Inch[N • m]

Applicable wire diameter

[AWG] (mm

2

)

2)

Recommended fuse

Voltage

Drive type

L1/R, L2/S, L3/T

1)

U. V. W

Control

section

L1/R, L2/S, L3/T

1)

U. V. W

Control
section

Fuse

[A]

3)

Gould

Company

Bussmann

Company

6KC1123F12X1**

3

A4J3

JKS3

6KC1123F25X1**

6

A4J6

JKS6

6KC1123F50X1**

10

A4J10

JKS10

6KC1123001X1**

15

A4J15

JKS15

6KC1123002X1**

14 (2.1)

20

A4J20

JKS20

6KC1123003X1**

10.6 (1.2)

12 (3.3)

30

A4J30

JKS30

3

-phase 230V input

6KC1123005X1**

15.9 (1.8)

10 (5.3)

40

A4J40

JKS40

6KC1121F12X1**

6

A4J6

JKS6

6KC1121F25X1**

6

A4J6

JKS6

6KC1121F50X1**

10

A4J10

JKS10

6KC1121001X1**

14 (2.1)

15

A4J15

JKS15

6KC1121002X1**

10.6 (1.2)

12 (3.3)

30

A4J30

JKS30

Single

-phase 230V

input

6KC1121003X1**

15.9 (1.8)

3.5

(0.4)

10 (5.3)

20

(0.5)

40

A4J40

JKS40

Drive type

Input max. volta

Input current

3 Phase input

AC230V

Single phase input

AC240V

5,000 A or less