Change during operation: N = impossible, Y* = possible (enabled by using ), Y= possible (enabled by using

)

-44-

FUNC

DATA

Electronic thermal O/L relay (thermal time constant)

0. 5

to

1 0. 0

The figure on the right shows the

continuous permissible current

with F10 (electronic thermal O/L

relay [Select]) = 1

.





The figure at right shows the
continuous permissible cur-
rent with F10 (electronic
thermal O/L relay [Select]) =
2. 100% of the continuous
permissible current is the
current value set with func-
tion F11 (electronic thermal
O/L relay [Level]).



˜ A ‘± ‹ – — e “d — ¬

( F 1 0 = 1 )

0

2 0

4 0

6 0

8 0

1 0 0

1 2 0

0

0 .2

0 .4

0 . 6

0 . 8

1

? o — Н? ь” g ? ”

/ Í? °? ( S о’к ) ? ь ”g ? ”

˜A‘±‹–—e“d—¬

[%]

F12

Factory

setting

Change during

operation

5.0min

Y*

This function sets the operating time of the electronic thermal O/L relay when the

current that is 150% of the operation level flows.

0.5 to 10.0 min. can be set (in 0.1 min. step).

Continuous permissible current (F10=1)

Continuous permissible current (F10=2)

Output frequency/base frequency

Continuous permissible

cu

rrent (%)

Output frequency/base frequency

Continuous permissible cu

rrent (%)

120

100

80

60

40

20

0

0 0.2 0.4 0.6 0.8 1