Change during operation: N = impossible, Y* = possible (enabled by using ), Y= possible (enabled by using

)

-48-

FUNC

DATA

DC injection brake

(starting frequency)

This function sets 3.0Hz (fixed) as the starting frequency of DC injection brake.



DC injection brake (Braking level)

This function sets a DC brake current level.

Levels can be set in 1% unit by assuming the level of the drive rated current to be 100%.


DC injection brake(Braking time)

This function sets the DC injection

braking time.

0.0 :

No DC injection braking

0.1 to 30.0 :

DC injection braking time 0.1

to 30s (in 0.1s step)

!

CAUTION

Do not use the drive brake function for

mechanical holding,

otherwise injuries could occur.

Output Freq.





3Hz



Time

Output voltage









DC injection brake

Factory

setting

Change during

operation

3.0Hz

N

F20

F21

F22

Factory

setting

Change during

operation

0%

Y

Factory

setting

Change during

operation

0.0s

Y