Change during operation: N = impossible, Y* = possible (enabled by using ), Y= possible (enabled by using

)

-47-

FUNC

DATA

Gain

(for frequency setting signal)

This function outputs the frequency obtained by multiplying the reference frequency by a ratio.

This function selects an analog input signal level with a value from 1 to

4 that is set by function F 0 1 .

0 The maximum frequency is output at +10Vdc (20mA dc).

1 The maximum frequency is output at +5Vdc (12mAdc).

When this function is used with function F 1 8 (bias frequency ), the gain set with this function is

valid and the gained frequency is biased.

Bias frequency

This function outputs a frequency biased for the analog frequency setting.

-1

2

0

to

1

2

0

Factory

setting

Change during

operation

0

N

-120 to 120Hz can be set with a resolution of 1Hz.

Factory

setting

Change during

operation

0

Y

0%

Bias (negative)

0

4

+10Vdc

20mAdc

100%

Frequency set-

ting

Bias (positive)

F17

100%

Frequency

setting

+10Vdc

+5

0

20mAdc

12

4

1

0

F18