Common specifications

Item

Specifications

Remarks

Maximum
output fre-
quency

50 to 120Hz (in 1Hz steps)

Base
frequency

25 to 120Hz (in 1Hz steps)

Starting fre-
quency

1 to 6Hz (in 1Hz steps)

Setting

Carrier fre-
quency

0.75 to 15kHz

(Vector-distribution PWM control selectable at 7kHz or less)

When operating at a carrie r frequency of 9kHz or above, the frequency
may automatically drop to 8kHz to protect the drive.

Accuracy

Analog setting:

±

1.0% of maximum frequency (at 25

±

10°C)

Keypad panel setting:

±

0.01% of maximum frequency

(at –10 to +50°C)

Output frequency

Setting reso-
lution

Analog setting: 1/256 of Maximum frequency

Keypad panel setting: 0.1Hz(99.9Hz or less), 1Hz(100Hz or more)

Voltage/

freq.

Characteristic

Output voltage proportional to input voltage. Base frequency

adjustable from 25 to 120Hz.

Torque boost

Manual setting by code 0 to 31.

(setting for variable torque load available)

Starting torque

150% or more (at 6Hz)

Control method

Sinusoidal PWM control

(with simplified current-vibration suppression)

Operation
method

Keypad operation: RUN or STOP key :

Input signal: Forward/Reverse/Stop command, Coast-to-stop

command, Trip command (External alarm),
Alarm reset

Frequency set-

ting

(Multistep)

(Linked opera-

tion)

Keypad operation: ,Digital setting by

or

key

Built-in potentiometer

Analog input: 0 to +5Vdc, 0 to +10Vdc, 4 to 20mAdc

Up to 4 multistep frequencies can be set in 2-bit external signal by terminal

function selection

Setting by RS485 serial communication (Option)

Acceleration/
deceleration
time

0.01 to 60.0s

(Independently adjustable acceleration and deceleration)

Frequency
limiter

High and low limits can be set for output frequency between 0 to 100% in

Hz

Bias frequency

The bias frequency can be set from –100 to +100% in Hz.

Control

Gain (frequency
setting signal)

5Vdc or 10Vdc gain can be selected.

Advertising