Caution – GE Industrial Solutions AF-300 C11 User Manual

Page 40

Advertising
background image

Change during operation: N = impossible, Y* = possible (enabled by using ), Y= possible (enabled by using

)

-38-

FUNC

DATA

5-2

Details of Each Function

Data protection

Set data can be locked to prevent it from being changed by mistake when using the keypad panel:

0

Data can be changed.

1

Data is protected.

Data is changed when the

STOP

+

or

key are pressed simultaneously.

Frequency command

The following five values can be selected:

0

Key operation [

key

]

1

Voltage input (terminal 12) (0 to + 10Vdc)

2

Current input (terminal C1) (4 to 20mA)

3

Voltage input (terminal 12) + current input (terminal C1)

4

Analog setting (POT built in drive)

!

CAUTION

High-speed operation can be set by the drive easily. Carefully check the limit of the motor and

machine before changing the setting,

otherwise injuries could occur.

F00

Factory

setting

Change during

operation

0

N

F01

Factory

setting

Change during

operation

4

N

Advertising