5 -36

Agilent Technologies Z5623A Option H48

Performance Verification

Verifying Return Loss and Insertion Loss Specifications

Verifying Return Loss and Insertion Loss
Specifications

Measurements Using The Reflection Port

Step 1. Connect an RF cable from Port 1 of the network analyzer to Test Port 1

of the test set. Connect another RF cable from Port 2 of the network
analyzer to the Reflection Port of the test set. See

Figure 5-39

.

Figure 5-39

Setup for Measuring Insertion Loss and Return Loss of Test Set

Step 2. Command the test set to connect the test port to the Reflection Port.

Consult

Table 3-2 on page 3-9

for a list of commands.

Step 3. Recall the limit test file for insertion loss. It is listed in

Table 5-3 on

page 5-7

.

Step 4. Read the results of the insertion loss test on the screen of the network

analyzer. Record the results in

Table 5-8

.

Step 5. Recall the limit test file for return loss (port active). It is listed in

Table

5-3 on page 5-7

.

Step 6. Read the results of the return loss (port active) test on the screen of the

network analyzer. Record the results in

Table 5-8

.

E8358A

(300 kHz - 9.0 GHz)

Port 1

Port 2

1

2

3

4

5

6

Reflection

Transmission

7

8

GPIB

GPIB

Advertising