Troubleshooting the viper pro system, Viper pro troubleshooting information, General issues – Seed Hawk Raven 2010 User Manual

Page 199: Chapter 11, Chapter

Advertising
background image

CHAPTER

11

Manual No. 016-3001-003

189

Chapter 11

Troubleshooting the

Viper Pro System

This chapter contains information on troubleshooting the Viper Pro system. Please read through all sections in

this chapter before contacting technical support, as many common questions are answered here.

Viper Pro Troubleshooting Information

This section contains information about possible issues and solutions for the Viper Pro

system

.

General Issues

Issue

Possible Cause

Solution

Viper does not

power up.

• No power to unit

• Check for +12VDC on pin 16 of the Viper power cable.

• Blown fuse

• Check for continuity in 10 amp fuse in Viper power cable.

• Poor ground

• Make sure that pin 1 is connected to the battery ground.

CAN nodes not

detected.

• No power to CAN nodes

• Verify that there is 12 volt power and ground to the CAN node's

logic power

• Weak or dirty power to

the CAN nodes

• Verify that the 12 volt power to the CAN node is coming from the

switch relay that is connected to the battery

• Water in CAN nodes

• Do not direct any pressure or wash stream directly at the CAN

node(s) to prevent water and moisture from building up in the

nodes.

• Corrosion in CAN

connections

• Disconnect and clean the CAN connections.

• Broken cable to node

• Repair or replace cable.

• Low power voltage

• Verify at least +10VDC at node.

Touch screen does

not respond to touch

• Area touched does not

include a selectable

function

• Touch an area of the screen that contains a selectable function.

• System is busy

processing a previous

request

• Wait for system to finish processing previous requests.

Advertising