Seed Hawk Raven 2010 User Manual

Page 48

Advertising
background image

Chapter 3

38

Seed Hawk™ Viper Pro™ Installation & Operation Manual

Decimal Shift

Use the Decimal Shift feature to increase the system accuracy for low application rates. In the standard mode,

the Viper Pro displays values to one decimal place. With the Decimal Shift feature enabled, values will be

displayed to two decimal places.

Note:

After you have either enabled or disabled the Decimal Shift, verify all calibration values for
accuracy. Change settings as necessary.

Agitator

Enable or disable the vehicle’s agitator via the Viper Pro console using this option. Contact your local Raven

dealer for required hardware.

Display Smoothing

With the Display Smoothing feature enabled, the target rate displays as the R

A

(actual rate applied) on the

Viper Pro main screen as long as the target rate is within 10% of the actual application rate. The actual rate

displays if the vehicle does not reach the deadband within 10 seconds.

With Display Smoothing disabled, the actual application rate displays at all times as the R

A

in the Application

Rates area on the Viper Pro main screen.

Note:

The display smoothing feature is only active for products in Automatic control mode.

Ratio Rate

The Ratio Rate may be enabled or disabled to allow an injected chemical to be applied in ratio to the amount of

the carrier. The Ratio Rate should only be enabled with chemical injection applications.

Advertising