11.

To verify the calculated value:

a.

Press OK on the Miscellaneous Settings screen to return to the CAN Controller Status screen.

b.

Touch the Tally Registers button at the bottom of the screen.

c.

Touch the Reset button next to the Distance display on the Tally Registers screen.

d.

Re-run the same test distance driven during the Calibration Assistance procedure. If the Distance

display on the Tally Registers screen matches the measured test distance, the calculated speed cal is

correct. If the Distance display does not match, see Appendix C, Calculating Speed Calibration, for

additional speed cal calibration procedures.

Audible Alarms

Viper Pro can sound a five second alarm tone whenever a CAN alert condition is encountered (i.e. low tank or

bin, zero speed, etc. Audible Alarms are enabled by default.

Node Version Information

Pressing the Next button on the Miscellaneous Settings screen will display the Node Version Information

screen. The Node Version Information screen displays the software version, software revision, and program

number of each node currently detected by the Viper Pro CANbus.