Seed Hawk Raven 2010 User Manual

Page 69

Advertising
background image

Manual No. 016-3001-003

59

CAN (Controller Area Network) Setup

The following table discusses the alarms and the conditions that will set off an alarm for products 4 or 5.

Alarm

Condition

Off Rate

This alarm activates when the actual application rate differs from the specified percentage

rate for more than five seconds, This alarm activates only when the system is in Auto mode.

The alarm automatically clears when the target rate and actual rate are within the specified

range or when the product mode is switched to either Manual or Off.

Low Limit

This alarm activates when the volume per minute has dropped below the specified limit.

This alarm activates only when the system is in Auto Mode. The alarm automatically clears

when the volume per minute rises above the specified limit or when the product mode is

switched to either Manual or Off.

Low Tank

This alarm activates when the tank volume has dropped below the specified limit. The alarm

can be cleared when you either enter a value that is above the low tank value or when you

enter a zero in the Low Tank field.

Flow/Shaft

For an injection application, the Flow alarm is active. This alarm activates to indicate a loss

of product flow. For a granular application, the Shaft alarm is active. This alarm activates

when the shaft sensor in a granular application does not detect shaft rotation. You must

troubleshoot the system to determine the cause of the alarm and clear it.

Vac/Bin

For an injection application, the Vac alarm is active. This alarm activates when the vacuum

sensor detects a vacuum in the tank. You must troubleshoot the system to determine the

cause of the alarm and clear it. For a granular application, the Bin alarm is active. This alarm

activates when the bin level sensor detects that the granular level in the bin drops below the

sensor.

Dual Flow

This alarm activates for an injection application system when the flow switch monitor and

the actual flow readings are out of the specified tolerance. This alarm also activates when

Gran 3 is selected as the application type and the rates sensed by the dual encoders are out

of the specified tolerance.

Zero Speed

This alarm activates when the speed of the vehicle drops below 0.7 MPH and the Zero

Speed Shutoff function is enabled. Cycle the master switch to clear the alarm and resume

product control.