Appendix D

208

Seed Hawk™ Viper Pro™ Installation & Operation Manual

Valve Speed Digit

This value controls the response time of the control valve motor. If you set the valve speed too fast, the valve

will over correct and the system can start to oscillate. The following valves have specific values:

Standard Control Valve: This valve has a range of values from 1 to 9, with 1 being slow and 9 being fast.

Fast and Fast Close Control Valve: These valves have a range of values from 0 to 9, with 0 for fast and 9

for slow.

Brake Point Digit

The Brake Point digit sets the percent away from the target rate at which the control valve starts to turn at a

slower rate so that it does not overshoot the target rate. The values range from 0 to 9, where 0 is a 5% rate, 1

is a 10% rate, and 90 is a 90% rate.

Dead Band Digit

The Dead Band digit is the allowable difference between the target rate and the actual application rate. The

values range from 1 to 9, where 1 equals 1% difference and 9 equals 9% of the difference.

Verifying Flow Rate Limits

The flow rate of application of a liquid product must be within the range of that specified for the flow meter. The

following table displays the flow meter, range, and average calibration number.

Calculating Meter Calibrations

The flow meter calibration value is stamped on the tag that is attached to each flow meter. Use this number

when programming Viper for the calibration.

Flow Meter Model

Flow Range

Average Meter Cal

Value

RFM 5

0.05 to 5 GPM

5500

RFM 15 F

0.3 to 15 GPM

1750

RFM 60P/S

1 to 60 GPM

720

RFM 100

3 to 100 GPM

700

RFM 200/200 Poly

15 to 200 GPM

164

RFM 400

25 to 400 GPM

80