Mechanical Data – W2F0

SC19D033-W2F0

SC19D038-W2F0

SC19D045-W2F0

Standard Dry Cooler Match

1 x DR40

1 x DR55

1 x DR55

Capacity

Nom Cooling (Gross) – W2

(1)

kW

29.1

36.8

42.3

Nom Cooling (Gross) - F0 (Free Cooling)

(2)

kW

61.6

67.9

74.4

Total Heat of Rejection –W2

kW

36.7

46.0

53.1

Capacity Steps

2

2

2

Fan Gain

(5)

kW

0.66

1.0

1.7

Dimensions - W x D x H

mm

1985 x 890 x 1980

1985 x 890 x 1980

1985 x 890 x 1980

Weight - Machine / Operating

kg

850 / 880

860 / 890

860 / 890

Construction

Panels: Galvanised Sheet Steel, Epoxy Baked Powder Paint - Black Grey (RAL 7021)

Material/Colour

Frame: Anodised Aluminium Frame with Black Nylon Corners

Evaporator

Rifled Copper Tube/Turbulated Hydrophilic Coated Aluminium Fins

Cooling/Dehum Stages

2/1

2/1

2/1

Condenser

(3)

Stainless steel Brazed Plate

Water Volume

l

2.5

6.1

6.1

Glycol Flow

l/s

1.8

2.26

2.6

Pressure Drop Condenser

kPa

76.8

55.5

72.8

Glycol Coil

Copper Tube/Turbulated Hydrophilic Coated Aluminium Fins

Water Volume

l

29.4

32.4

32.4

Glycol Flow

l/s

2.3

2.26

2.95

Pressure Drop F0

kPa

31.6

47.2

60.1

Unit

Water flow

l/s

1.8

2.26

2.6

Pressure drop

kPa

108.44

102.7

132.86

Dry Cooler

Water Volume

L

23.1

43.2

43.2

Flowrate

l/s

1.8

2.26

2.6

Pressure Drop

kPa

40.8

27.5

33.7

Fan Motor

Backwards Curved, Centrifugal direct drive

Motor Type

EC

EC

EC

Quantity x Motor Size

kW

2 x 2.2

2 x 2.2

2 x 2.2

Speed @25Pa ESP/ maximum ESP

rpm

964 / 1360

1117 /1360

1340 /1360

Maximum ESP

Pa

438

302

49

Nominal Airflow

m³/s

3.7

4.3

5.1

Compressor - Scroll

Configuration

Dual Cool - Circuit 1 Tandem Compressors (Water Cooled)

Circuit 2 Free Cooling

Quantity - W2

2

2

2

Oil Charge Volume - W2

l

2 x 1.57

2 x 1.57

2 x 1.57

Oil Type

Polyolvinyl

Connections

Inlet/Outlet

mm

35

35

35

Condensate Drain Hose

mm

22

22

22

Filtration

Disposable to BS EN 779-G4

Quantity

3

3

3

OPTIONAL EXTRAS

Hot Gas Reheat - X

Nom Heating (Gross)

kW

8.3

9.2

9.7

Electric Heating (Total)

kW

21

21

21

Humidifier

Capacity

kg/hr

8

8

8

Feed/Drain

3/4" BSPF Braided flexible hose / 19mm hose connection

Condensate Pump

Head

m

10.8

10.8

10.8

Flow

l/m

5

5

5

Drain

10mm Stainless Steel Stub Connection

First upgrade Fan Motor - EC Motor

Backwards Curved, Centrifugal direct drive

Quantity x Motor Size

kW

2 x 3.1

2 x 3.1

2 x 3.1

Speed @ 25Pa

rpm

986 / 1520

1145 /1520

1364 / 1520

Maximum ESP

Pa

589

453

216

Fan Gain

(5)

kW

0.65

1.03

1.73

Second upgrade Fan Motor - EC Motor

Backwards Curved, Centrifugal direct drive

Quantity x Motor Size

kW

N/A

N/A

N/A

Speed @ 25Pa

rpm

N/A

N/A

N/A

Maximum ESP

Pa

N/A

N/A

N/A

Fan Gain

(5)

kW

N/A

N/A

N/A

Low Pressure Hot Water

(4)

Copper Tube/Aluminium Fin

Capacity Gross

kW

22.2

24.5

26

Water Flow (Nominal)

l/s

0.49

0.54

0.58

Pressure Drop

kPA

9.4

9.7

10.1

LPHW Connection Sizes

mm

22

22

22

(1) Entering air 24°C/ 45% RH condenser water in / out 35 / 40°C
(2) Entering air 24°C/ 45% RH condenser water in / out 7/12°C and based on water.
(3) Pressure drop through condenser, free cooling coil, 3 port valve, Head pressure control valve and unit pipe work
(4) Based upon low pressure hot water 82°C inlet/71°C outlet. Air on 20°C
(5) Fan gain based on 25Pa ESP @ nominal air volume. Fan gain will change as airflow and ESP change.

W